Experimental determination of the sensitivity of Bloch Surface Waves based sensors

Data di pubblicazione: 1 Apr 2010

RivistaFonte dati: OPENALEXTipo OpenAlex: articleOpen Access
Autori: Fabrizio Giorgis, Emiliano Descrovi, Caterina Summonte, Lorenzo Dominici, Francesco Michelotti

Detection of glucose in water solution for several different concentrations has been performed with the purpose to determine the sensitivity of Near Infrared Bloch Surface Waves (lambda = 1.55microm) upon refractive index variations of the outer medium. TE-polarized electromagnetic surface waves are excited by a prism on a silicon nitride multilayer, according to the Kretschmann configuration. The real-time reflectance changes induced by discrete variations in glucose concentration has been revealed and analyzed. Without using any particular averaging strategy during the measurements, we pushed the device detection limit down to a glucose concentration of 2.5mg/dL, corresponding to a minimum detectable refractive index variation of the water solution as low as 3.8.10(-6).

Fonte
Optics Express
Volume
18
Fascicolo
8
Pagine
8087
Citazioni
114
ID archivio
3993e2f73e905ec13a80ed554e315c50
Riferimenti
Volume: 18 Issue: 8 Pages: 8087-8093